RADIATION MONITOR YANTAR-1A

APPLICATION
Used at VEHICLE (TRUCK) checkpoints.

Detection threshold, no more than:

Cs - 137
300 kBq
Co - 60
150 kBq
Ba - 133
240 kBq
Pu
3 g
U
315 g
Pu in shielding
80 g
Note: Pu is a sample of highly enriched plutonium Pu-239, U is a sample of highly enriched uranium U-235.

Registration channels
gamma, neutron
Gamma detector
4 plastics of 4.6 l
Neutron detector
12 counters of 0.6 l
Control zone parameters
width
6 m
height
4 m
Object speed
15 km/h
Power consumption
80 W
Operating temperature
From -50°С to +50°С
Dimensions of one rack
795x3057x370 mm
Total weight
700 kg

The probability of detecting the reduced masses of nuclear materials is 0.5 with a confidence level of 95%, background intensity of no more than 20 μR/h and a false alarm rate of no more than 1/1000.

Note:

The sensitivity of the gamma channel can be increased by replacing the gamma detector: 4 plastics of 7.1 l;
Can be supplied in a single-rack design;
Can be supplied without a neutron channel.