Component Near Field Indicator Frequency Counter NR-D
$
$
Submit a request
The component indicator of the near field frequency meter "NR-D" is designed to search, detect and localize the places of hidden installation of various types of radio transmitting devices in the active mode.
The device informs the operator about the detection of a radio transmitting device by means of light and sound indication.
"NR-D" has three main operating modes:
- SEARCH
- MONITORING
- VIEWING THE PROTOCOL
Technical specifications 1. Frequency range of the power detector channel: 50 – 3500 MHz 2. Frequency range of the component channel: 50 – 3000 MHz 3. Power detector channel:
- threshold sensitivity at the input, no more than: -60 dBm; - dynamic range of indication: 50 dB; - frequency meter sensitivity: - 50 dBm; - measurement error of the frequency of a continuous signal, no more than: 1%; - pulse signal frequency measurement error, no more than: 10% 4. Component channel: - input threshold sensitivity, no more than: -60 dBm; - dynamic range: 60 dB; 5. Non-volatile memory capacity: 2048 events 6. Power supply: NiMH AA batteries (2 pcs.) 7. Dimensions: 135*70*25 mm 8. Weight: 0.2 kg