RADIATION MONITOR YANTAR-2U

APPLICATION
Used at VEHICLE (CAR) checkpoints.

Detection threshold, no more than:

Cs - 137
390 kBq
Co - 60
190 kBq
Ba - 133
315 kBq
Pu
5 g
U
480 g
Pu in shielding
95 g
Note: Pu is a sample of highly enriched plutonium Pu-239, U is a sample of highly enriched uranium U-235.

Registration channels
gamma, neutron
Gamma detector
2 plastics of 4.6 l
Neutron detector
6 counters of 0.6 l
Control zone parameters
width
6 m
height
3 m
Object speed
15 km/h
Power consumption
60 W
Operating temperature
From -50°С to +50°С
Dimensions of one rack
651x2073x300 mm
Total weight
390 kg
The probability of detecting the reduced masses of nuclear materials is 0.5 with a confidence level of 95%, background intensity of no more than 20 μR/h and a false alarm rate of no more than 1/1000.

Note:

Can be supplied in a single-rack design;
Can be supplied without a neutron channel.
See also