Astrophysics XIS-5878 X-ray television introscope

Features of the XIS-5878 introscope:
Display of the image of the inspected objects in 6 colors, depending on the atomic number. 6-color display makes it easier for the operator to identify the materials of the inspected object and speeds up the inspection procedure itself.
A continuous diagnostic system in real time, allowing users to monitor the condition of the equipment and prevent premature failure. Due to this, the service life of the equipment increases.
A large set of functions in the basic configuration.
Russian keyboard and software.
Standard functions (in the basic package)
Separation of materials by three or six colors depending on the atomic number and density
Organic/inorganic separation
Enhanced Picture Perfect image
Smooth image enlargement from 1 to 64 times (ZOOM)
2x enlargement by 9 image areas
Moving the enlarged image on the screen
Atomic number measurement
Color and black and white image
Compensation for geometric distortion
Negative image
Pseudo color
Contouring
High penetration function
Real-time image management
Automatic image archiving (up to 150,000 images)
Browsing the image library (up to 100 images)
Manual saving of images
Baggage counter
Continuous inspection
Scanning in both directions
Multi-level access
Possibility of connection to a local network via TCP/IP protocol for remote monitoring and diagnostics
Training program operators
Printer connection option
Real-time diagnostics
Selecting opaque areas of an image
Powerful conveyor belt drive
Creating comments to images
Russified software and operator console
Printer connection option
Technical specifications:
Main specification

Tunnel size: 584 mm x 783 mm
Overall dimensions: 2524 mm x 1371 mm x 1260 mm
Packaging dimensions: 1910 mm x 1473 mm x 1600 mm
Conveyor speed: 0.23 m/s
Conveyor height: 300 mm from the floor
Conveyor traction force: 165 kg
Design: steel frame with panels
Weight: 635 kg
Weight in packaging: 900 kg
Inspection capabilities

Resolution: 40-38 AWG
Spatial Resolution: 1.0 mm horizontally, 1.0 mm vertically
Penetration (in steel): 39-37 mm
Contrast sensitivity: 24 color tones, 4096 shades of gray
X-ray generator

Anode voltage: 180 kV (working 165 kV)
Radiation source: sealed, maintenance-free bulb
Source current: 1.2 mA
Cooling: air-cooled oil bath
Beam direction: horizontal
Detector array: L-shaped, 1664 channels
Computer

Processor: Intel® Core i5
Memory: 4 GB RAM
Hard drive: HDD 500 GB, SSD 120 GB
Video card: 1 GB, dual display output
OS: Windows OS
Voltage stabilizer: 600VA
Video

Display type: two 19” LCD monitors
Display resolution: 1280 x 1024, 24-bit color
Operation

External operating conditions: temperature 0 - +40C
Storage temperature: -20 - +60 C
Humidity: up to 95% (non-condensing)
Power: 220V (+ /- 10%), 50Hz, 10A max
Safety

Compliance with standards: USFDA (21-CFR 1020-40)
Standard radiation leakage less than 0.1 mR/h (the permitted value in accordance with US government standards is less than 0.5 mR/h).