Monitoring and security system SIG-1

The system is designed for remote operational control of object movement using a portable infrared volumetric sensor, a repeater with an actuator (hereinafter IA) and a base station (hereinafter BS).

The BS receives an alarm from the sensor via a radio channel when moving objects enter the working area of ​​the sensor (or sensors).

An IA is installed to increase the communication range between the sensor and the BS. When the sensor is triggered, a relay in the IA can be switched on to activate external devices.

ADVANTAGES

1. Reliable operating system.

2. Small dimensions of the sensors.

3. Possibility of remote sensor design

4. The sensor operates for 30 days on one battery.

5. Works over long distances

6. Low cost of the sensor

7. Possibility of activating devices. Relay in the actuator.

TECHNICAL CHARACTERISTICS

Communication range between BS and type A sensor, not less than

500 m. (in open areas)

Communication range between BS and sensor with IS

1500 m. (in open areas)

Frequency range

800-900 MHz

Number of connected sensors

From 1 to 6

Sensor response distance

Up to 5 m. (see Fig. 2)

Sensor response range (depending on version)

Up to 1100 (see Fig. 2)

Sensor power supply, not less than

3 V

Sensor power supply

LIR2032(TIA A)/

ACCU(TYPE B)

Sensor operating time

about 1 month at 100 response times per day

Dimensions sensor

55x24x16 mm

Sensor weight no more than

60 gr.

BS power supply

3.7 V (built-in battery)

BS operating time not less than

18 hours

Operating temperature, °C

-20/+50

BS dimensions (without external antenna)

90x60x25 mm

BS weight not more than

120 g

IU power supply

3.7 V (built-in battery)

IU operating time not less than

24 hours

Operating temperature, °C

-20/+50

IU dimensions

125x50x40 mm

BS weight not more than

130 g

Sensor protection

IP65

BS protection

IP64

IU protection

IP64

BS indicator units

Color OLED display, vibration signal, headphone output, LED
See also