The external device interface unit "Sonata-SK4.2" (hereinafter referred to as the Product) is a specialized controller - a 220 V network switch. The main purpose of the Product is to interface the electric drive of window sashes with a complex of technical means of information protection TSZI (3090, 3095, 3105, 3109), installed in a dedicated room with opening windows. The load (electric drive) is controlled by applying/disconnecting the 220 V power supply voltage to one of the two inputs ("Forward", "Reverse"). The Product is connected to the TSZI complex via the power supply and control line ReBus 3(3). Electric drive control commands can be transmitted remotely (from the Sonata-IP4.x unit) or by manual control buttons located on the body of the Sonata-SK4.2 product. The product is programmed in such a way that when the TSZI complex is activated, the window is forced to close, with remote control commands having priority. Upon completion of the active operation of the TSZI complex, the window sashes are set to the previously set position.
The Sonata-SK4.2 product is part of the Sonata-AV model 4B system and is certified as its component.
Main technical characteristics of the Sonata-SK4.2 product.
Parameter Value Number of control channels 1 Power and control unit "Sonata-IP4.x" Supply voltage, V 12 ± 2 Load capacity, A, not less than 1 Control interface ReBus-3 (3) Product power supply, V, not less than 10 Current consumption, mA, not more than 20 Duration of continuous operation, h, not less than 8 Overall dimensions, mm, not more than dimensions and weight of products
Operating mode (state) The product can be controlled by the LED indicator "Mode" located on its top panel in accordance with Table 1.
Table 1
Operating mode Actions Indication Protection off The window is open. Manual control buttons "Open", "Close" - work. Rare flashes of the green indicator. Protection on The window is closed. Buttons "Open", "Close" - do not work. The indicator lights up green continuously Emergency A system malfunction has been detected The indicator flashes red Protection is disabled The window is closed. The "Open" button is working "Flickering" of the green indicator
Window is moving Frequent flashes of the green indicator
Instructions for connecting the Giesse Varia Uni 230V drive to the "Sonata-SK4.2" interface unit.
1. Remove the "Sonata-SK4.2" interface unit and the Giesse Varia Uni 230V drive from the package. 2. Install the drive according to the installation instructions included with it. 3. Install the interface unit in a convenient location. 4. Make the connection in accordance with Fig. 2. 5. Configure the TSZI complex according to the method described in the operating manual for the "Sonata-AV" model 4B system.