The ST122 signal simulator is an updated model of the ST121 signal simulator. The main differences of the new model are:
- Availability of FM modulation;
- Extended range of the microwave emitter. 13-14 GHz.
- Working with the signal simulator via a personal computer.
ST122 is designed to simulate:
Information transmission channels used by special technical means of covert information acquisition (STS NPI) Nonlinear effect when connecting to wired lines of STS NPI Side electromagnetic radiation of STS NPI Application area Training Conducting laboratory tests and measurements Monitoring the performance of search devices and equipment ST122 provides generation of:
Radio signals with arbitrarily selectable frequency values in the range of 100 - 6000 MHz, adjustable output power, AM, FM and FSK modulation, the method of transmitting frequency hopping, SPS and SCP Microwave signals in the range of 13-14 GHz Signals simulating digital data transmission standards (GSM 2,3,4G, DECT, BLUETOOTH and WLAN) LF and HF signals to the 220V network and low-current lines IR signal with LF modulation signal and selection of subcarrier frequency Sound and ultrasonic signals, both with arbitrarily selected frequency values, and with frequencies corresponding to the values of octave and three-octave filters. Direct connection of the dynamic emitter to the output connector ST122 is provided Low-frequency magnetic field simulating the PEMI of electronic equipment (dictaphones, smartphones, etc.)
ST122 can be controlled from a Windows-compatible PC using special software "ST122.Remote" with the ability to create your own signal database
soft
Firmware update via the Internet
Technical specifications
HF-microwave output Frequency range, MHz 100-6000 Frequency step, kHz 10, 100, 1000, 10000, 100000 Signal level, dBm minus 42 - plus 14 Modulation type AM, FM, FMn Transmission method frequency hopping, SCP. ShPS Frequency hopping range, MHz 1, 5, 10, 20, 50, 100 Number of frequency hopping channels 10, 25, 50 ShPS band, MHz 0.3, 0.5, 1, 2, 4 Signal transmission time SCT, sec 0.0001- 99 SCT accumulation time, sec 0.01-5999 Simulated data transmission standards GSM, 3G, 4G, DECT, WLAN and BLUETOOTH
Microwave radiation source "Microwave" Frequency range, GHz 13-14 Modulation AM, FM Power supplied to antenna, dBm 10
Output "RJ-45" Frequency range, kHz 0.01-20000 Maximum signal amplitude, V 3.5 Modulation type AM, FM, PWM Pulse repetition frequency, Hz 1.10, 20, 50, 100 Duty cycle 1, 5, 10, 20
Output "220V"
Frequency range, kHz 30-20000 Maximum signal amplitude, V 3.5 Maximum permissible input voltage, V 380 Modulation FM, PWM
Frequency range, kHz 0.01-120 Frequency selection is arbitrary, octave and three-octave Maximum output power, W 0.7 Minimum load resistance, Ohm 8 Modulation AM, FM, PWM
Magnetic field source "IMP" Equivalent magnetic moment of the magnetic field source at a frequency of 1 kHz, A*m2 2*10-4
USB interface
Power source built-in Li pol battery, 2.2A/h Power supply 5V 2A Dimensions, mm
Main unit (without antenna) 110X60X28 Packaging 255X170X65