RADIATION MONITOR RM-1SM

APPLICATION
Used at checkpoints in OFFICES.

Detection threshold, no more than:

Cs - 137,360 kBq
Co - 60,180 kBq
Ba - 133,340 kBq
Pu 6 g
U 400 g
Note: Pu is a sample of weapons-grade plutonium, U is a sample of weapons-grade uranium U-235.

Registration channels
gamma
Gamma detector
1 plastic 0.8 l
Control zone parameters
width
0.7 m
height
2 m
Object speed
5 km/h
Power supply
12 V DC
Output
RS 485 protocol MODBUS' RTU
Power consumption
20 W
Number of racks with detectors
1
Dimensions of one rack
1370 x Ø110 mm
Total weight
9.5 kg
Detection thresholds for radioactive and nuclear materials are given at a detection probability of 0.5 with a confidence level of 95%, background intensity of no more than 20 μR/h, false alarm rate of no more than 1/1000, control zone parameters and object speed specified in the table.