INSPECTION AND CHECKING COMPLEX (ICC) HCV CAB 2000 MA

Main advantages
Quick installation / turn-on time - less than an hour
High throughput and excellent image quality thanks to modern HiTraX technology and image processing software
X-ray system creates 24-bit images in real time
High penetration with a low radiation dose
The HCV SAV 2000 MA X-ray inspection system is designed to detect contraband in trucks and sealed containers during customs clearance. The combination of high penetration with a low radiation dose makes the SAV 2000 MA system an excellent X-ray inspection tool. The system consists of two modules: This functional module is on the platform of a 20-foot container and a transport module - a standard vehicle with a removable body (class C 745, EN 284). The layout of the system allows for quick inspection of transported goods without the need to open containers or trucks.

The system technology facilitates the implementation of this unit in almost all inspection systems and infrastructures. The system can be installed or dismantled in less than an hour. Thanks to its fast connection, the system is suitable, in particular, for processing express requests and is used at various sites as part of the inspection process. The system is based on the advanced HI-SCAN X-ray inspection technology, which is used in thousands of installations worldwide.

TECHNICAL DATA

General technical data

Nominal energy (MeV)

4 MeV, pulsed beam

Scanning principle

object passing through the inspection system

Penetration power

250 mm (9.8 in)

X-ray dose/inspection

on steel typically 0.5 µSv (0.05 mlRem)

System specifications

Dimensions (W x D x H)

9m x 15m x 6m (29.5 ft x 49.2 ft x 19.7 ft)

Scanning height

0.2 m - 4.2 m (0.7 ft - 13.8 ft)

Max. height under gantry

4.5 m (14.7 ft)

Operating personnel (min.)

2 operators

Recommended personnel

1 receiving operator, 1 system operator, 2 image operators

Operating / storage temperature

-10 °C - 40 °C / -25 °C - +60 °C (14 °F - +104 °F / -13 °F - +140 °F)

Humidity

10% - 90% (non-condensing)

Power supply

400 V AC, three-phase • 50 Hz / 60 Hz ± 3 Hz built-in power generator, external power supply

Power consumption

approx. 20 kVA

Max. standard dimensions

2.6 m x 20.0 m x 4.2 m • 98.4 ft x 787.4 ft x 165.4 ft • other object sizes on request

Computer system

Monitor

22-inch color monitor b/w, color

Image presentation

HIGH, LOW, NEG, VARI-CAT, SEN, REVIEW (recall of previous image areas)

Image evaluation functions

scaling: 2x, 3x, 4x magnification of the image presentation system (IMS)

Video memory

electronic 1280 x 1024 / 24 bit

Radiation protection measures

Surveillance

CCTV system, light protective fences

Radiation leakage rate

meets all applicable legal standards and regulations for X-ray devices

Conformity to standards

CE marking in accordance with directives 98/37/EWG, 73/23/EWG, 89/336/EWG

Film safety

guaranteed up to ISO 1600 (33 DIN)

Health protection and safety

Radiation dose to the environment

less than 0.5 μSv/h (average, external safety zone) and less than 1 mlSv/year

Radiation dose rate in the operator's cabin

μSv/h (average value) and less than 1 mlSv/year

The system consists of two modules:

A functional module placed on a 20-foot platform container.
Transport module, motor vehicle (25 t) with a swap body (class C 745)
HCV CAB 2000 MA
See also