INSPECTION AND CHECKING COMPLEX (ICC) HCV CAB 2000 MA
$
$
Submit a request
Main advantages Quick installation / turn-on time - less than an hour High throughput and excellent image quality thanks to modern HiTraX technology and image processing software X-ray system creates 24-bit images in real time High penetration with a low radiation dose The HCV SAV 2000 MA X-ray inspection system is designed to detect contraband in trucks and sealed containers during customs clearance. The combination of high penetration with a low radiation dose makes the SAV 2000 MA system an excellent X-ray inspection tool. The system consists of two modules: This functional module is on the platform of a 20-foot container and a transport module - a standard vehicle with a removable body (class C 745, EN 284). The layout of the system allows for quick inspection of transported goods without the need to open containers or trucks.
The system technology facilitates the implementation of this unit in almost all inspection systems and infrastructures. The system can be installed or dismantled in less than an hour. Thanks to its fast connection, the system is suitable, in particular, for processing express requests and is used at various sites as part of the inspection process. The system is based on the advanced HI-SCAN X-ray inspection technology, which is used in thousands of installations worldwide.
TECHNICAL DATA
General technical data
Nominal energy (MeV)
4 MeV, pulsed beam
Scanning principle
object passing through the inspection system
Penetration power
250 mm (9.8 in)
X-ray dose/inspection
on steel typically 0.5 µSv (0.05 mlRem)
System specifications
Dimensions (W x D x H)
9m x 15m x 6m (29.5 ft x 49.2 ft x 19.7 ft)
Scanning height
0.2 m - 4.2 m (0.7 ft - 13.8 ft)
Max. height under gantry
4.5 m (14.7 ft)
Operating personnel (min.)
2 operators
Recommended personnel
1 receiving operator, 1 system operator, 2 image operators
Operating / storage temperature
-10 °C - 40 °C / -25 °C - +60 °C (14 °F - +104 °F / -13 °F - +140 °F)
Humidity
10% - 90% (non-condensing)
Power supply
400 V AC, three-phase • 50 Hz / 60 Hz ± 3 Hz built-in power generator, external power supply
Power consumption
approx. 20 kVA
Max. standard dimensions
2.6 m x 20.0 m x 4.2 m • 98.4 ft x 787.4 ft x 165.4 ft • other object sizes on request
Computer system
Monitor
22-inch color monitor b/w, color
Image presentation
HIGH, LOW, NEG, VARI-CAT, SEN, REVIEW (recall of previous image areas)
Image evaluation functions
scaling: 2x, 3x, 4x magnification of the image presentation system (IMS)
Video memory
electronic 1280 x 1024 / 24 bit
Radiation protection measures
Surveillance
CCTV system, light protective fences
Radiation leakage rate
meets all applicable legal standards and regulations for X-ray devices
Conformity to standards
CE marking in accordance with directives 98/37/EWG, 73/23/EWG, 89/336/EWG
Film safety
guaranteed up to ISO 1600 (33 DIN)
Health protection and safety
Radiation dose to the environment
less than 0.5 μSv/h (average, external safety zone) and less than 1 mlSv/year
Radiation dose rate in the operator's cabin
μSv/h (average value) and less than 1 mlSv/year
The system consists of two modules:
A functional module placed on a 20-foot platform container. Transport module, motor vehicle (25 t) with a swap body (class C 745) HCV CAB 2000 MA