APPLICATION Metallurgical and waste processing plants; Nuclear power plants; Plants for the extraction, storage and processing of nuclear materials; Military nuclear installations and storage facilities. Detection threshold, no more than:
Cs - 137 170 kBq Co - 60 85 kBq Ba - 133 145 kBq Pu 2.5 g U 250 g Note: Pu is a sample of highly enriched plutonium Pu-239, U is a sample of highly enriched uranium U-235.
Registration channels gamma Gamma detector 4 plastics of 11.5 l each Control zone parameters width 6 m height 4 m Object speed 15 km/h Power consumption 40 W Operating temperature From -50°С to +50°С Dimensions of one rack 860x2660x300 mm Total weight 500 kg The probability of detecting the reduced masses of nuclear materials is 0.5 with a confidence level of 95%, background intensity of no more than 20 μR/h and a false alarm rate of no more than 1/1000.