Active protection device for information leakage due to information signal interference on power supply and grounding circuits "Sonata-RS3".
Attention! The "Sonata-RS3" device is manufactured and supplied only with guarantees of its intended use.
The active protection device for information leakage due to information signal interference on grounding and power supply circuits "Sonata-RS3" (hereinafter referred to as the Product) is designed to protect information containing state secrets and other information with limited access processed by technical means and systems from leakage due to information signal interference on grounding and power supply circuits and can be installed in dedicated premises up to and including category 1.
The design features of the devices allow for effective and inexpensive solutions when equipping a computer facility with a large number of computer equipment (CET). There is also the possibility of local wired control (remote control "Sonata-DU4.2") in case of use as part of the TSZI 2400 complex. The product can be included in the TSZI complex. In this case, its operation and monitoring of the operating mode (serviceability) will be carried out from the control panel "Sonata-DU4.1" in combination with the power supply "Sonata-IP4.x" (Complex 3095, Complex 3109). When working with the wired control panel Sonata-DU4.2, monitoring of the status and operating mode of the device can be carried out both directly (light indication on the front panel of the devices), and using the light and sound indication of the Sonata-DU4.2 remote control. For more detailed information, see the Operation Manual for the Sonata-DU4.2 device. When operating as part of a TSZI complex, which includes a Sonata-IP4.2 power supply and control unit, the status and operating mode can also be monitored via the Ethernet network using the Inspector software.
Obtaining operating time counter data in the "Emission" mode is possible: Using the Sonata-PS4 service information reading console. When operating as part of a TSZI complex based on a Sonata-IP4x power supply and control unit, obtaining operating time counter data is possible using the Kamerton software. Option for installing Products at a VT facility with one 220V line input in Fig. 1, with two inputs in Fig. 2.
The products are designed for connection to a 3-wire power supply network ("Phase", "Zero" and "Protective grounding") and ensure the formation of non-phase currents and common-phase and paraphase components of noise voltage in all conductors. If the connection diagram is violated, the presence of all components, as well as the value of the integral noise level, may not be ensured.
Main technical characteristics:
Characteristic Value Types of indication (displayed information) Light, sound (serviceability / failure) Operating time counter Yes, duration - at least 7 years Remote control 1) control panel "Sonata-DU4.1" in combination with the power supply and control unit "Sonata-IP4.x"; 2) control panel "Sonata-DU4.2" Power supply network ~220 V +10%/-15%, 50 Hz Power consumption, W, no more than 10 Duration of continuous operation, hours, no less than 8 Overall dimensions (HxLxW), mm, no more than dimensions and weight of products Length of network cable, m, no less than 1.2